Extracorporeal Magnetotransduction System Therapeutic Device Water Cooling Continuous 1200W Output Power

Still deciding? Get samples of $ !
Request Sample

Product Description

Extracorporeal Magnetotransduction System Therapeutic Device with Water Cooling and 1200W Output Power

The PMST MAX DUO is a cutting-edge, dual-technology physical rehabilitation device engineered to redefine professional pain management and accelerate recovery from musculoskeletal and sports injuries. This robust system strategically combines High-Intensity Pulsed Magnetic Therapy (HIPMT), delivering a powerful 7 Tesla (7T) magnetic field, with advanced Low-Power Diode Light Therapy (LPLT) utilizing synergistic 650nm and 808nm wavelengths.

Basic Information
Model NO. GMS PMST DUO max
Theory Rehabilitation Machine
Certification CE, ISO13485
Technology Sports Medicine Rehabilitation Device
Type Pulsed Magneto Therapy + Near-Infrared Laser
Magnetic Energy 4t, 7t Standard, 5t Optional (2 Channels)
Laser Wavelength 650nm + 808nm
Laser Power 5600MW
Work Mode MT (Magneto) + ST (Shockwave Therapy Equivalent)
Cooling System Air Cooling + Closed Water Circulation
Display Screen 10.4" True Color LCD Touch Screen
PMST MAX DUO System
Technology Principles
High-Intensity Pulsed Magnetic Therapy (HIPMT)

This device delivers a powerful magnetic field strength of up to 7 Tesla (7T). This energy ensures a non-contact, pain-free, and non-invasive treatment that penetrates deeply into tissues, passing through skin, fat, and bone to act on neurons, muscle tissue, and blood vessels.

Dual-Mode Frequency Control:
  • MT Mode (1 - 150 Hz): Focused on Regeneration and Repair. Boosts cellular metabolism and circulation to alleviate chronic inflammation.
  • ST Mode (1000 - 3000 Hz): Focused on Acute Pain Relief. Rapidly blocks pain signal transmission for a powerful analgesic effect.
Low-Power Diode Light Therapy (LPLT)

LPLT utilizes precisely calibrated diode light energy for Photobiomodulation of biological tissues, initiating biochemical reactions without heat.

  • 650nm Wavelength: Accelerates surface wound healing and regulates scar tissue by promoting epithelial cell growth.
  • 808nm Wavelength: Achieves deeper penetration to accelerate the production of ATP, fueling deep tissue repair and regeneration.
Clinical Applications
Detailed Photos
Professional Pain Management
  • Chronic Pain: Lower back pain, cervical spondylosis, and tension headaches.
  • Acute Injuries: Muscle sprains, ligament strains, and swelling reduction.
  • Joint Conditions: Osteoarthritis (knees, hips, shoulders) and herniated discs.
Sports Medicine & Rehabilitation
  • Tendon Pathologies: Tennis elbow, golfer's elbow, and Achilles tendinitis.
  • Muscle Conditioning: Relaxation of muscle spasms and prevention of disuse atrophy.
System Features
Industrial-Grade Cooling

Equipped with an advanced Water Circulation Cooling System, removing significant heat quickly to allow for up to 8 hours of continuous operation in busy clinical environments.

Professional Ergonomic Applicators
  • Standard Muscle/Point Applicators: For large groups and targeted points.
  • Optional Joint Applicator: Shaped for complex anatomical structures.
  • Optional Laser Applicator: Dedicated handpiece for precise LPLT control.
Safety & Contraindications
Strictly Prohibited:
  • Implants: Cardiac pacemakers, defibrillators, or metallic implants.
  • Malignancy: Areas affected by tumor diseases.
  • Pregnancy: Strictly contraindicated for pregnant women.
  • Specific Tissues: Eyes, heart muscle, spinal cord, and growth cartilage in children.
  • Bleeding Disorders: Patients with coagulation issues or using anticoagulants.
Product Visuals
Product View 1
Product View 2
Product View 3
Product View 4
Frequently Asked Questions
What is the core technology behind the PMST MAX DUO?
The system combines High-Intensity Pulsed Magnetic Therapy (7 Tesla) with Low-Power Diode Light Therapy (650nm and 808nm) for comprehensive tissue repair and pain relief.
What is the difference between MT and ST modes?
MT Mode (1-150Hz) is designed for tissue regeneration and chronic inflammation repair, while ST Mode (1000-3000Hz) provides rapid analgesic effects for acute pain.
Why does the device use two different laser wavelengths?
The 650nm wavelength targets superficial wound healing and skin surface recovery, while the 808nm wavelength penetrates deeper to stimulate ATP production for internal tissue repair.
How long can the machine work without stopping?
Thanks to its industrial-grade water circulation cooling system, the device can operate continuously for approximately 8 to 12 hours.
How long does a typical treatment session last?
Depending on the condition being treated and the area involved, sessions typically last between 20 to 40 minutes.
What are the main contraindications for this therapy?
Treatment is strictly prohibited for patients with cardiac pacemakers, metal implants, malignant tumors, blood disorders, and during pregnancy.